<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-13 14-35-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 73 dBuV SR P3
Pilot RDS Phase Difference
6.5 kHz 3.4 kHz 76 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 27 kHz 14746 0,4611
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-2,2 dBr -0,89 dBr 0,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SR P3 " E203 0 (No PTY) 0 1 1 1 13:35, 13.07.2025
RT
"SR P3 "
AF EON
90.7, 92.6, 95.5, 97.9, 98.5, 98.6, 99.0, 99.4, 100.5 MHz 6B42, E201, E224, E402
FM Scope Max at: 27 kHz MIN: 10 kHz % above 76 kHz: 0,4611 Acquired: 2025/07/13 14.34.36 Total samples: 14746 Equivalent time: 0:12:17 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 0,7 dBr MIN: -2,2 dBr AVE: -0,89 dBr % above 12,2 dBr: 0,0 Last value: -2,0 dBr (2025/07/13 14.34.36) 14.20 14.22 14.24 14.26 14.28 14.30 14.32 14.34 -3 -2 -1 0 1 Pm [dBr]